Kanga Sandford Termination Wattmeter
In making the decision to purchase this kit, I scoured the internet for reviews. eHam turned up empty. KC9ON did have an excellent write-up, as did M0XPD, but that was it. For this reason, I feel compelled to share my thoughts.
Overview
The Sandford Termination Wattmeter is built around four 50Ω thick film resistors, a diode detector circuit, and an ammeter (with a custom scale) to show RF power. It has two selectable ranges for 5 W and 20 W. The kit also features an RF sample tap with an RCA jack on the front panel. I paid $90 including tax, shipping and tariffs in September 2026.

One important note is that this kit is a termination wattmeter, as the name suggests. RF does not pass through the device. It cannot be used inline with an antenna, and it cannot be reversed to measure reflected power. It is most similar to a Bird Termaline wattmeter, or the QRP-Labs 20 W dummy load with an enclosure and a meter added to the RF detector.
The front panel of the enclosure is double-sided, and can be installed to orient the meter horizontally or vertically. I chose to build mine vertically. The front panel is differently (incorrectly?) labeled in the manual and some of the marketing photos for this kit, calling it the "Standford" wattmeter with a -36 dB tap. My example labels the sample tap -34 dB, which matches my calculations of the circuit.
Construction
The kit is constructed Manhattan-style on top of a double-sided custom PCB. The build instructions (pdf) were fine, but would have benefited from color photographs of each step. This was my first Manhattan-style kit, and I found it straightforward to adapt to the different soldering technique.
Note the four large resistors in the center of the board. The two 1/4 watt axial resistors form the rest of the -34 dB attenuator for the sample tap, and the diode in the background is the 1N4148 diode for the RF detector.
Final assembly was the most difficult part of the build. Once the board was mounted inside the enclosure, short, thin wires and limited soldering angles made finishing the wiring awkward. 
Here's a close up photo of the installed circuit board from below. The one modification I made to the kit was to sand off the powder coat behind the BNC connector to give a better ground connection for the enclosure. 
And here is the view from above, with the calibration potentiometer visible. Note the structural ground wire. The back of the circuit board is mechanically suspended by this wire. 
Calibration and Theory
Calibrating the wattmeter is straightforward, and can be done with a regulated DC voltage source. Calibration can be done either during the initial construction phase or by applying the reference DC voltage across the BNC connector with the 5W range selected. The manual specifies that calibration should be done with a regulated 12 V supply, and the variable potentiometer adjusted until the meter reads 1.5 W. However, a typical bench 13.8 V supply can also be used as a 2 W reference.
The detector circuit is charging a capacitor to the peak RF voltage and measuring a tiny current through a calibrated load (fixed resistor + potentiometer + meter coil), and correlating it to RF power. Any voltage that corresponds to a convenient power output within the meter's range can be used.
Testing
Using a calibrated NanoVNA and the NanoVNASaver desktop application, I swept the wattmeter from 1-100 MHz. SWR was ~1.05 for most of the range, as expected for a dummy load. The slight mismatch is attributable to the load impedance of the dummy load being 48.4Ω, slightly below the 50Ω characteristic impedance of the VNA. I would feel comfortable using this as a dummy load up to 60 MHz. The markers on the curves below are for the 80m, 20m, 10m and 6m bands. Frequency scale is logarithmic.

The manual suggests that this meter has +/- 10% accuracy. I did hook it up to my QCX+ which I have previously measured with the QRP-Labs 20 W dummy load to have 6.5 W output at 13.8 V. The Sandford meter showed 7.5 W, which seems high, but may well be correct. I plan to more thoroughly evaluate the meter accuracy as I continue to use it, but for most QRP tasks, it seems good enough.
One nitpick: a 5 W scale is a poor max range. Almost every QRP radio has a 5 W output (and most slightly exceed it), which pins the meter on low range. 2 W and 8 W (QRPp and QRP), or 15 W and 60 W (QRP and medium power from a small amplifier) would be more useful operating ranges for a QRP wattmeter. Kanga isn't the only manufacturer making this mistake.
I do not have a spectrum analyzer or oscilloscope, so I have not used the RF tap yet.
Final Thoughts
In my opinion, this kit is great for the modern QRP enthusiast. Build a new QRP-Labs rig and want to safely check its power output? Experimenting with a Low Pass Filter for a homebrew transmitter and want to attenuate the output before connecting your spectrum analyzer? With the advent of NanoVNAs, the relevance of the power/swr meter is decreasing, as more useful information than SWR alone can be gathered from the VNA. However, a good BNC dummy load with a power meter in a professional enclosure will always have a place on my bench. I have no idea why this kit is not more common.